FIBER OPTICAL GYFTY53-12
Classification
Coax 75Ω | 50Ω
Brand
OEM
Product origin
China
Delivery time
25 days
Supply capacity
10000km
Inquiry
Download
Product Description
1.Structure description
Non-metal FRP Strength member, loose tube type,gelly filled, Polyethylene(PE) sheath, outerdoor optical fiber cable for telecommunication.
1.1 Technical characteristics:
Non-metal Strength member,Loose tube stranding type, gelly filled, Polyethylene(PE) inner sheath, PSP armor and Polyethylene(PE) outer sheath, Outerdoor optical fiber cable for telecommunication
1.2 Technical characteristics:
- Very strict material and manufacturing control guarantees stable product quality.
-Total cross-section water-resistant structure make cable have an excellent properties of moisture resistance
- Special jelly filled in the loose tube provides the fibers with critical protection
-The central member adopted corrosion resistant, high young's modulus phosphatic steel wire.
-PSP armor structure has super crush resistance.
-Double-sided plastic strip (PSP) moisture-proof layer
2. Cable Specification
2.1 The both cable ends are sealed with heat shrinkable end caps to prevent water ingress.
2.2 Fiber color and Binder color code: according to EIA/TIA 598B
Non-metal FRP Strength member, loose tube type,gelly filled, Polyethylene(PE) sheath, outerdoor optical fiber cable for telecommunication.
1.1 Technical characteristics:
Non-metal Strength member,Loose tube stranding type, gelly filled, Polyethylene(PE) inner sheath, PSP armor and Polyethylene(PE) outer sheath, Outerdoor optical fiber cable for telecommunication
1.2 Technical characteristics:
- Very strict material and manufacturing control guarantees stable product quality.
-Total cross-section water-resistant structure make cable have an excellent properties of moisture resistance
- Special jelly filled in the loose tube provides the fibers with critical protection
-The central member adopted corrosion resistant, high young's modulus phosphatic steel wire.
-PSP armor structure has super crush resistance.
-Double-sided plastic strip (PSP) moisture-proof layer
2. Cable Specification
2.1 The both cable ends are sealed with heat shrinkable end caps to prevent water ingress.
2.2 Fiber color and Binder color code: according to EIA/TIA 598B
No |
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
Fiber Color
|
Blue
|
Orange
|
Green
|
Brown
|
Slate
|
White
|
Red
|
Black
|
Yellow
|
Violet
|
Pink
|
Aqua
|
*According to the customer required for color scheme.
2.3 Loose tube color scheme
2.4 Color codes for Loose Tube (LT) & Filler Rod (FR)
2.3 Loose tube color scheme
2.4 Color codes for Loose Tube (LT) & Filler Rod (FR)
Element No. |
|||||||||||
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
LT
|
LT
|
FR
|
FR
|
FR
|
FR
|
-
|
-
|
-
|
-
|
-
|
-
|
3 Cable structure and parameter
Fiber
|
12 B1.3(G652D)
|
Tube diameter (mm)
|
1.8 mm
|
Fiber per tube
|
6
|
Class Yarn(root)
|
10
|
Central Strength member (mm)
|
1.9mm FRP
|
Outer Sheath thickness (nominal*)(mm)
|
1.5mm
|
Inner Sheath thickness (nominal*)(mm)
|
0.9mm
|
Steel tape thickness(mm)
|
0.23mm
|
Water blocking tape thickness(mm)
|
0mm
|
Cable diameter (nominal**)(mm)
|
11.9mm
|
Weight (approx.)(kg/km)
|
130kg/km±5%
|
Max.allowable pulling force(N)
|
Installation:3000/operation1500
|
Crush resistance(N/100mm)
|
2500
|
Min bend radius(mm)
|
Long-term 10 OD
Short-term 20 OD |
Operating temperature range
|
-40℃ to +60℃
|
Storage / Transport temperature range
|
-20℃ to +60℃
|
Installation temperature range
|
0℃ to +60℃
|
12 cores Total unit number (LT+FR)
|
6(2LT+4FR)
|
* The nominal sheath thickness may vary by ±0.2mm.
** The nominal outer diameter and height may vary by ±0.4mm. ***LT means: loose tube. FR means: Filler rod. |
4. Main mechanical & environmental characteristics test
No |
Item
|
Test Method
|
Acceptance Requirements
|
1
|
Tensile Strength
IEC 794-1-E1 |
- Load: 3,000 N
- Length of cable under load: 50m |
- Loss change 0.1 dB @1550 nm
- No fiber break and no sheath damage. |
2
|
Crush Test
IEC 60794-1-E3 |
- Load: 1, 000 N/100mm
- Load time: ≥1min |
- Loss change 0.1 dB @1550 nm
- No fiber break and no sheath damage. |
3
|
Impact Test
IEC 60794-1-E4 |
- Points of impact: 5
- Times of per point: 5 - Impact energy: 4.5Nm - Radius of hammer head: 12.5mm - Impact rate: 2sec/cycle |
- Loss change 0.1 dB @1550 nm
- No fiber break and no sheath damage. |
4
|
Repeated Bending
IEC 60794-1-E6 |
- Bending Dia.: 20 x OD
- Load: 250N - Flexing rate: 3sec/cycle - No. of cycle: 30 |
- Loss change 0.1 dB @1550 nm
- No fiber break and no sheath damage. |
5
|
Torsion
IEC 60794-1-E7 |
- Length: 1m
- Load: 150N - Twist rate: 1min/cycle - Twist angle: ±180° - No. of cycle: 10 |
- Loss change 0.1 dB @1550 nm
- No fiber break and no sheath damage. |
6
|
Water Penetration
IEC 60794-1-F5B |
- Height of water: 1m
- Sample length: 3 m |
- No water shall have leaked from
the opposite end of cable |
7
|
Temperature Cycling
IEC 60794-1-F1 |
- Temperature step:
+20oC→-40oC→+60oC →+20oC - Time per each step: 24 hrs - Number of cycle: 2 |
- Loss change 0.1 dB @1550 nm
- No fiber break and no sheath damage. |
8
|
8 Compound Flow
IEC 60794-1-E14 |
- Sample length: 30 cm
- Temp: 70°C 2°C - Time: 24 hours |
- No compound flow
|
9
|
Sheath High Voltage Test
|
- On line test
- 9t KV (t-sheath thickness) |
- No sheath breakdown
|
5. Packing and Marking
5.1 Packing
5.1.1 Each single length of cable shall be reeled on Fumigated Wooden Drum OR Iron-wooden
drum suitable for long distance shipment.
5.1.2 Covered by plastic buffer sheet.
5.1.3 Sealed by strong wooden battens.
5.1.4 At least 1 m of inside end of cable will be reserved for testing.
5.1.5 Drum length
5.1.5.1 Standard drum length is 2100m±100m;
5.1.5.2 Single length not less than 96% of standard length per drum shall be permitted for quantity
not exceeding 10% of the total supply;
5.1.5.3 Total quantity is at least the ordered quantity.
5.2. Drum Marking
5.2.1 Cable drum
- Manufacturer brand;
- Roll-direction arrow;
- Cable outer end position indicating arrow;
- The word “FIBER OPTICAL CABLE”;
- Origin, The word “MADE IN CHINA”;
- Caution plate indicating the correct method for loading, unloading and convey the cable;
- Other customer information such as contract no., project no., and delivery destination.(if needed)
5.2.2 Marking plate
- Product name;
- Cable type and size;
- Drum length;
- Gross / Net weight in kilograms;
- Drum number in meters;
- Manufacturer's name;
- Manufacturing year and month;
- Project number, contract number or purchasing order number (if needed).
5.3 Cable identification documents
- Test report.
5.1 Packing
5.1.1 Each single length of cable shall be reeled on Fumigated Wooden Drum OR Iron-wooden
drum suitable for long distance shipment.
5.1.2 Covered by plastic buffer sheet.
5.1.3 Sealed by strong wooden battens.
5.1.4 At least 1 m of inside end of cable will be reserved for testing.
5.1.5 Drum length
5.1.5.1 Standard drum length is 2100m±100m;
5.1.5.2 Single length not less than 96% of standard length per drum shall be permitted for quantity
not exceeding 10% of the total supply;
5.1.5.3 Total quantity is at least the ordered quantity.
5.2. Drum Marking
5.2.1 Cable drum
- Manufacturer brand;
- Roll-direction arrow;
- Cable outer end position indicating arrow;
- The word “FIBER OPTICAL CABLE”;
- Origin, The word “MADE IN CHINA”;
- Caution plate indicating the correct method for loading, unloading and convey the cable;
- Other customer information such as contract no., project no., and delivery destination.(if needed)
5.2.2 Marking plate
- Product name;
- Cable type and size;
- Drum length;
- Gross / Net weight in kilograms;
- Drum number in meters;
- Manufacturer's name;
- Manufacturing year and month;
- Project number, contract number or purchasing order number (if needed).
5.3 Cable identification documents